IMPORTANTEnsure there is no contact with any of the internal parts of
the terminal box.
Briefly reconnect the mains power supply to the pump – the ‘power on’ light
should illuminate if the pump has been correctly wired.
Isolate the mains electrical power supply from the pump.
Re fit the terminal box lid ensuring no cables are trapped.
Re fit the four terminal box lid retaining screws, tighten to 0.8 Nm.
‘Power on’ light
Terminal box lid
Retaining screws x 4
Fig. 18 Wiring removed for clarity