Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the home owner as it contains
important guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products:
Turbo 20SNH
Pt. No. 49055
Turbo 30SNH
Pt. No. 46056
Turbo 15TNH
Pt. No. 49050
Turbo 20TNH
Pt. No. 49049
Turbo 30TNH
Pt. No. 49048
*3 year as standard extended to 4 years with a Techflange fitted
FOR POSITIVE OR NEGATIVE HEAD APPLICATIONS
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the home owner as it contains important guarantee, ma

Page 2 - CONTENTS

- 10 -Cont ...3. Check in the mouth of the fitting that ‘O’-ring, nylon washer and collet are in position.4. Push pipe firmly into fitting, unti

Page 3 - Sealing Washer

- 11 -Cont ...4 ELECTRICAL INSTALLATION / EARTHING4.11 Regulations: The electrical installation must be carried out in accordance with the cu

Page 4

- 12 -Cont ...4.23 Supply Cord Replacement:The supply cord and internal wiring within the terminal box are routed and secured to ensure compliance wi

Page 5 - 2 LOCATION - GENERAL

- 13 -Cont ...4.24 Cable Gland Fitting Instructions: To enable correct assembly of the cable gland the ‘O’-ring (Fig. 14 item 1) must be placed

Page 6 - 2 LOCATION - SINGLE PUMP

- 14 -Cont ...5 COMMISSIONING5.11 System Flushing: This pump incorporates push-in connectors and plastic components that must not come into con

Page 7 - 2 LOCATION - TWIN PUMP

- 15 -Cont ...5.14 Starting: a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then stop. b

Page 8

- 16 -Cont ...6 MAINTENANCE6.11 Turn off water supplies to the pump and release pressure by opening water outlets before attempting maintenance.

Page 9 - 3 PUMP CONNECTIONS

- 17 -Cont ...6.14 Pressure vessel: The pressure vessel air charge does not require routine maintenance. Should ever the need arise for the ves

Page 10 - Cont

- 18 -Cont ...7 TECHNICAL SPECIFICATIONTechflow reserve the right to amend the specification in line with its policy of continuous development of its

Page 11 - Diagram of

- 19 -8 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu

Page 12 - Fig. 13

- 2 -Cont ...PRODUCT DESCRIPTIONElectric motor driven twin ended peripheral pump, complete with an automatic control system, consisting of flow switch

Page 13

- 20 -Cont ...8.11 Dry Run Protection: This pump is fitted with a PCB that will detect the following fault conditions:  Dry running caused by wat

Page 14 - 5 COMMISSIONING

- 21 -Cont ... IMPORTANT – Ensure there is no contact with any of the internal parts of the terminal box.  Briefly reconnect the mains power su

Page 15

- 22 -Cont ...8.14 Flow Switch Circuit Test: 1. First confirm visually that the flow switch reed clamps have not been dislodged during handl

Page 16 - 6 MAINTENANCE

- 23 -Cont ...9 THE TECHFLOW GUARANTEE Congratulations on purchasing a Techflow pump. We are confident this pump will provide many years of troubl

Page 17 - Schrader valve

DECLARATION OF CONFORMITY2006/42/ECBS EN ISO 12100-1, BS EN ISO 12100-2, BS EN 8092006/95/ECBS EN 60335-1, BS EN 60335-2-412004/108/ECBS EN 55014-1, B

Page 18 - 7 TECHNICAL SPECIFICATION

- 3 -CHECKLISTItemDescription QtyItemDescription QtyPump 1 Hose with isolating valve 2Hose 2Your product may vary slightly from the picture above.PRE-

Page 19 - 8 TROUBLE SHOOTING GUIDE

- 4 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to

Page 20

- 5 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must

Page 21 - Retaining screws x 4

- 6 -Cont ... The following method will help to overcome the problem: A “U” bend or downward loop in the supply pipe to the pump of 350 mm depth

Page 22

- 7 -Cont ...Cold water connection:2.27 The cold water supply: The supply must be air free and have a dedicated connection to the tank which sh

Page 23 - 01444 258017

- 8 -Cont ...Hot water connection:2. 29 Hot water cylinder or storage tank: When a hot water cylinder or storage tank is used, ensure the pipewor

Page 24 - Business Development Director

- 9 -Cont ...3 PUMP CONNECTIONS  Do not use stainless steel, chrome or nickel plated pipe with the flexible hose push-in plumbing connections.