To set switch for sump filling:
Assemble the float on the right hand side of the operating lever (as shown in Fig. 12).
The pump will switch off when the tank is full.
To set switch for sump emptying:
For draining a sump (low level cut out) assemble the float on the left hand side of the
operating lever (as shown in Fig. 11).
Fig. 11
Fig. 11
Counterbalance
weight
Float Switch
Upper level
stop
Float
Float
weight
Cord
Stop weight
Lower level
stop
Counterbalance
weight
Float Switch
Upper level
stop
Float
Float
weight
Cord
Stop weight
Lower level
stop